Hydroman® Slurry Pumps

Engineered for the toughest applications in handling slurries, rocks, gravels, sand, stones, sludge, mud, sewage, waste water and big solids.

Hydroman® TBZ415 High Head Submersible Pump

SPECIFICATIONS

Size 100 mm
Capacity 84 m³/h
Head 56 m
Power 15 kW
Handling Solids 11.5 mm
Mechanical Seal Mechanical seal
Materials Hyperchrome, SS304, SS316L, Duplex Stainless Steel etc

Hydroman® TBZ415 Submersible Pump

You have a long discharge line, a big elevation gain, and a pit full of liquid that is not clean water. A standard drainage pump will either stall against the head or wear out in a few weeks. The Hydroman® TBZ415 high head submersible pump is built for that situation. It is an electric, centrifugal, fully submerged pump that you lower into the pit, connect to your discharge line, and let work.

 

If you are replacing a KBZ415 on an existing site, the TBZ415 is designed as a direct replacement. It keeps the same high head, submersible slurry-handling concept and offers the same kind of installation and service experience.

 

 

TBZ415 High Head Submersible Pump Overview

 

The TBZ415 is a vertically oriented submersible pump that combines a sealed electric motor with a centrifugal wet end. The motor sits directly beneath or beside the hydraulic section, so there is no long drive shaft, no surface motor to protect from mud and weather, and no priming to worry about. The pump is already under the liquid when it starts.

 

The wet end uses an impeller slurry pump design. This means a thick, wear-resistant impeller and volute meant to move liquids that carry solids, such as bentonite mud, drilling fluid, sandy water and industrial sludge. Where a clear-water high head pump would clog, this kind of impeller keeps the flow moving.

 

Typical jobs include bentonite slurry circulation on piling and diaphragm wall projects, high head dewatering in deep excavations and mines, and effluent transfer from sumps to treatment or discharge points.

Key Features of the Hydroman® TBZ415

High head performance when the discharge line is long

Total head is more than the vertical lift. It is static height plus pipe friction, plus fittings, plus any pressure needed at the outlet. A pump that shows a good number on a brochure can still disappoint if the real system curve was never calculated. The TBZ415 is a high head centrifugal pump intended for high-resistance systems such as deep shafts, uphill slurry lines, and long runs through HDPE or steel pipe.

Electric submersible design, no engine to babysit

As an electric pump, the TBZ415 has no fuel tank, no exhaust, and much lower noise than a diesel unit. That matters in tunnels, basements, urban foundation projects and anywhere air quality or noise limits apply. A submerged motor is also cooled by the surrounding liquid, so you should keep it covered to the minimum submergence level in the manual and avoid prolonged dry running.

Slurry-ready centrifugal impeller

The impeller converts motor energy into velocity and then into pressure inside the volute. On a centrifugal slurry pump, the vanes are heavier, the passages are wider, and the material is harder than on a water pump. This keeps efficiency from falling off too fast as solids wear the casing. Many slurry impellers also include back vanes or an agitator to reduce recirculation and keep settled solids from packing the suction.

Built for continuous industrial duty

Slurry pumping is hard on shaft seals, bearings and liners. The TBZ415 is designed so that wear parts can be inspected and replaced without scrapping the whole unit. For jobs that run around the clock, that means planned maintenance instead of emergency stops.

Hydroman® TBZ415 High Head Submersible Pump

High Head Submersible Pump Curve

TBZ415 Technical Specifications

Engineers and buyers usually check the numbers first, so here they are. If you do not see your exact duty point, send us your flow and head and we will check it against the performance curve.

 

Brand / Model Hydroman® / TBZ415
Pump type High head submersible slurry pump, centrifugal
Drive Electric, three-phase submersible motor
Rated power 15 kW
Flow rate 84 m³/h
Total head 56 m
Discharge size 100 mm
Maximum solids passage 11.5 mm
Rated Current (400V) 29.5 A
Installation Fully submerged, vertical

 

Please download the TBZ415 datasheet and performance curve for the full rated data. Voltage, frequency and cable length can be customized to your site.

 

 

 

Submersible Bentonite Slurry Pumps

TBZ415 Pump for Bentonite Slurry Transfer

Bentonite slurry transfer

Bentonite is the standard support fluid for bored piles, diaphragm walls, horizontal directional drilling and slurry shield tunneling. A typical fresh mix uses about 4–6% bentonite by weight, giving a density of roughly 1.03–1.06 g/cm³ and a Marsh funnel viscosity in the region of 30–50 seconds. Once cuttings are carried in the slurry during excavation, density can climb to 1.10 g/cm³ or higher.

 

That is why people look for a bentonite pump rather than a water pump. The slurry is denser, thicker, and often thixotropic: it gels when it stops moving. A submersible bentonite pump like the TBZ415 can sit directly in the trench, mud pit or settling tank, and work as an electric bentonite slurry pump for circulation to the desanding plant and back. Contractors call it a bentonite mud pump or a centrifugal bentonite pump, but the requirement is the same: moderate solids, higher density, and enough head to reach the separation equipment.

 

One honest caveat: because bentonite is viscous, centrifugal pumps lose some head and efficiency compared with water. We size the pump from your actual slurry properties, not from the water-rated curve alone.

 

High Head Submersible Sewage Pump

Where the TBZ415 Works Best

High head slurry pumping

In mining, tunneling, quarrying and sand washing, a high head slurry pump has to push abrasive mixtures uphill or over long distances. The high head submersible slurry pump format is useful when the source is a sump or pond, because it removes suction-line problems. As a rule of thumb, slurry lines are often designed for a velocity of about 1.5–3 m/s: slow enough to limit pipe wear, fast enough to prevent solids from settling.

 

Industrial water transfer and dewatering

Excavations for metro stations, foundations and shafts can need heads of 50 m or more in staged pumping. As a high head dewatering pump and high head submersible water pump, the TBZ415 handles sandy or silty water that would destroy a light-duty drainage pump. If you only need clear water, a high head water pump with a standard impeller will usually cost less, and we will say so.

 

Effluent and wastewater transfer

For gritty industrial effluent, wash-down water and process sludge, the TBZ415 can work as a high head effluent pump. For sewage with rags, wipes or long fibres, use a pump with a cutter or a vortex/channel impeller instead of assuming any high head sewage pump will do. Tell us what is in the liquid and we will confirm.

 

Note: the TBZ415 is an industrial slurry and dewatering pump. If you are looking for a high head irrigation pump or a small high head sump pump for a house basement, a lighter product will be a better and cheaper fit.

High Head Centrifugal Pump

How to Select the Best Pump for High Head Duty

The best pump for high head work is the one that matches your system, not the one with the biggest head number. Four questions get you most of the way.

 

1. What flow and total head do you really need? Add static lift, friction loss in the pipe, losses in valves and bends, and the pressure you need at the end of the line. People often underestimate friction on long slurry lines.

 

2. What is in the liquid? Density, viscosity, particle size, solids concentration and abrasiveness decide the impeller, wear material and motor size. A pump that is perfect for 2% fine silt may not suit 20% coarse sand.

 

3. What motor power and supply do you have? For water, shaft power in kW is approximately Q × H ÷ (367 × η), where Q is flow in m³/h, H is head in m and η is pump efficiency. For slurry, multiply by the specific gravity. For example, 100 m³/h at 60 m head with 60% efficiency and a slurry SG of 1.1 needs about 30 kW at the shaft, and you should add a margin for the motor.

 

4. What are the installation conditions? Check minimum submergence, level swings, pit size, discharge hose or pipe route, and duty cycle. A pump that runs 24 hours a day has different needs from one used for a weekend pump-out.

 

Why Customers Choose Hydroman® TBZ415

You get a pump selected for your medium and duty, not one pushed from stock. Our team reviews the flow, head, solids and power supply before recommending a configuration. We list only the materials and options that are actually available, and we support you with spare parts, drawings and technical answers after the order.

 

If you are moving from a KBZ415, send the old nameplate details and your current duty point. We will check the TBZ415 against them so the swap is simple, with matching connections and minimal change to your pit setup.

 

Use this table as a quick filter:

Your situation What to look for
Deep excavation, sandy water High head dewatering pump with abrasion-resistant wet end
Bentonite circulation on piling or diaphragm wall Submersible bentonite pump sized for slurry density and viscosity
Abrasive mining or quarry slurry High head slurry pump with hard-metal impeller and liners
Fibrous sewage Cutter or vortex sewage pump, not a standard slurry impeller

 

 

 

Hydroman® TBZ415 Submersible Bentonite Slurry Pump Material of Construction

 

Hydroman Submersible Centrifugal Bentonite Pump Material Item No. Part name Material   Item No. Part name Material
01 Hose coupling Cast iron 28 Rotor Shaft: AISI420SS
02 Handle Rubber & steel 31a Bearing Ball bearing
05 Upper cover Cast iron 31b Bearing Ball bearing
11 Motor body Cast iron 33 Motor protector —
13 Pump body Cast iron 34 Mechanical seal Sic-Sic/Carbon-Sic (≤2.2kW)
Sic-Sic/Sic-Sic (≥3.7kW)
14 Impeller High chrome alloy 35 Oil seal —
16 Inlet plate Ductile iron 47 Cable —
25 Strainer Steel      
27 Stator —    

 

 

Hydroman® TBZ415 Electric Submersible Pump Dimensions & Weights

 

Hydroman Submersible Slurry Pump Dimensions Weight
Model (50/60Hz) TBZ415
d (mm) 100
A (mm) 373
A1 (mm) 255
B (mm) 842
D (mm) 350
H (mm) 755
W1 (mm) 190
N.W (Kg) 144
G.W (Kg) 158
Packing dimension(mm) 935x415x435

 

 

Frequently Asked Questions

 

What is a high head submersible pump?

It is a pump with a sealed electric motor that works underwater and is designed to deliver liquid against a large total head. Head, flow and pipeline resistance are linked: as the system resistance rises, flow drops along the pump curve. That is why the pump must be chosen for the duty point, not for the maximum head alone.

 

Can the TBZ415 handle bentonite slurry?

Yes, within the limits of slurry density, viscosity and solids size shown on the performance data. Bentonite is thicker than water and can gel when idle, so please share your mix ratio and expected density when you ask for a quote. We will confirm the duty point and any derating.

 

What is the difference between a high head water pump and a high head slurry pump?

A water pump uses a tighter, lighter impeller built for clean liquid and higher efficiency. A slurry pump uses wider passages, thicker walls and harder materials so it can move solids and survive abrasion. It is typically less efficient on clean water but lasts much longer on dirty duty.

 

How do I choose the right motor power for a high head pump?

Calculate it from flow, head, liquid density and pump efficiency, then add a safety margin. Check the motor against the full pump curve, not only the design point, so it does not overload when the system runs at a higher flow.

 

What information do I need to request a TBZ415 quotation?

Send the target flow, required head, liquid type, solids content and particle size, voltage and frequency, installation conditions, and quantity. A pit sketch or pipe layout helps even more.

 

Request a Quote for the Hydroman® TBZ415

Tell us what you are pumping, how high it has to go, and how long the line is. A pump specialist will reply with a recommended configuration, a performance curve, and a clear quotation.

 

 

Tobee is specialized in providing solutions for slurry pump, vertical sump pumps, gravel pump, dredging pumps, froth pump, seawater pumps, fire pumps, slurry pump parts and OEM pump parts for your harsh projects.

Contact Information

Contact Information

+86 180 3203 4573

+86 311 8722 1317

No. 266, Tianshan St, High-tech Zone, Shijiazhuang City 050000, China.

Copyright © Hebei Tobee Pump Co., Ltd. All Rights Reserved | sitemap.xml | sitemap.html | Privacy Policy